Alloy

Composition

Resistance (Ī©/ cmf)

 

Density(lb./in3)

Tensile Strength - annealed (ksi)

Suggested MAX Operating Temp (°F)

KP

90% Ni / 10% Cr

425

0.315

95

2300

KN

95%Ni/5%(Mn,Si,Al,Co)

177

0.311

85

2300

JP

99.5% Fe

60

0.284

65

1400

JN

45Ni / 55 Cu

300

0.322

60

1400

EP

90 % Ni / 10% Cr

425

0.315

95

1600

EN

45Ni / 55 Cu

300

0.322

60

1600

TN

45Ni / 55 Cu

300

0.322

60

700

NP

14 Cr/1.5Si/Bal Ni

585

0.307

90

2300

NN

4.5 Si / 95.5 Ni

215

0.314

65

2300

Alloy 11

1 Ni / 99 Cu

25

0.322

40

400