Standard Calibration Temperatures
Listed below are the standard temperatures at which we calibrate our material. Calibration at other temperatures is possible, and can be made available for most cable.
 
Equipment
A pod furnace is used to calibrate most of the mineral insulated cable (aka MgO, MI cable) produced at Idaho Laboratories. An oil bath is also available on a limited basis for calibrating items that cannot be accomodated in the furnaces.
 

Type

Temp. Range (F)

Calibration Temperatures (F)

K

32 to 2300

449, 1220, 1981

J

32 to 1400

449, 787, 1220

E

32 to 1600

449, 787, 1220

T

-75 to 700

449

T (cryogenic)

-300 to -75

-320
-109
 
 *Please note that the calibration temperature ranges listed above are based on ASTM E-230 specifications, and the expected use of the material. We can calibrate at other temperatures as needed. If your requirements are different, please ask us. We can be reached by phone at (208) 522-0055 or sales@idaholabs.com.